   PCU2 mk5 Primary Current Injection System
  Product Links
   
  Primary Injection System
  Secondary Current Injection
  High Voltage AC Test Systems
  High Voltage DC Test Systems
  MicroOhmmeters
   
  Documents
   
  Data Sheet
  Data Sheet
   
 
   
  Related Product
   


DVS3 Digital Voltage Source

 

 

 

 

 

 

 
 

Overview
The PCU2 mk5 primary current injection system is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables.
 

 

Model PCU2 mk5 Control Unit with
an LU5000 Loading Unit

Features

  • 20kV five (5) minute output capability.
  • Continuously variable output.
  • Multi-function timing system.
  • Digital true RMS memory ammeter.
  • Bright LED displays.
  • Automatic switch-off at end of test.
  • Centralized control and metering.
  • Separate control and loading units.
  • Output up to 10KA.
  • Low impedance, dual-range outputs

 

 
 
The control unit may be used with one of two loading units providing between 5000 Amps or 6000 Amps for five minutes or up to 10KA or 12KA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the LU6000 may be configured to either give a maximum current of 3000 Amps at 6.6 Volts or 6000 Amps at 3.3 Volts.

The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have small plan area to allow them to be positioned as close as possible to the test object, minimizing power requirements and maximizing the available current.

The PCU2 mk5 control unit is shown here with an LU5000 loading unit. This combination may be used to inject currents of up to 5000 Amps for 5 minutes, 8000 Amps for 5 seconds or 10000 Amps for 1 second. This unit is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing.

The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips

A flexible timing system is provided, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and overcurrent devices, reclosers, under and over voltage devices, current trips and circuit breakers.

   
 
 